Modular system for end-of-line testing of battery systems including BMS controller. Test of cell behaviour and BMS functionality.
Power supply, safety technology and components such as insulation monitors and measuring devices, voltage and current measuring components are housed and wired separately from the application module in the test system cabinet. Defined safety mechanisms ensure that there is no danger to life and limb even in the event of potential incorrect operation of the test system. The application module contains all functions and circuits that are dependent on the respective DUT. If another DUT with a modified test connection is to be tested later, only this module needs to be replaced.